DSLR

Hasselblad 500 mech.

The Hasselblad 500 mech. is a DSLR with a Medium format 53.4 × 40 mm sensor measuring 54.5 × 36.4 mm. Its crop factor is 0.66× — wider than full frame, so a 50 mm lens frames like 33 mm. Every number below is calculated for this exact sensor.

Medium format 53.4 × 40 mm0.66× cropHasselblad V
0.66×
Crop factor
54.5×36.4 mm
Sensor size
1983 mm²
Area · 230% of full frame

Specifications#

Model
500 mech.
Camera type
DSLR
Lens mount
Hasselblad V
Sensor size
54.5 × 36.4 mm (Medium format 53.4 × 40 mm)
Crop factor
0.66×

Specifications merged from Lensfun. Spot an error? Tell us.

Sensor size compared#

Hasselblad 500 mech.Medium format 44 × 33 mmFull frame (35 mm)APS-CFour Thirds / Micro Four Thirds
The Hasselblad 500 mech. sensor (highlighted) drawn to scale against common formats. Its area is 230% of a full-frame sensor.

Focal length equivalents & field of view#

Multiply any focal length by 0.66 to get the full-frame field of view. Angles are for a rectilinear lens focused at infinity.

Lens on this cameraFull-frame equivalentHorizontalVerticalDiagonal
21 mm14 mm104.8°81.8°114.7°
23 mm15 mm99.7°76.6°109.9°
28 mm18 mm88.5°66.0°99.0°
32 mm21 mm80.9°59.2°91.4°
35 mm23 mm75.9°54.9°86.2°
45 mm30 mm62.4°44.0°72.1°
55 mm36 mm52.8°36.6°61.6°
63 mm42 mm46.8°32.2°55.0°
80 mm53 mm37.7°25.6°44.6°
90 mm59 mm33.7°22.8°40.0°
110 mm73 mm27.9°18.8°33.2°
120 mm79 mm25.6°17.2°30.6°
150 mm99 mm20.6°13.8°24.7°
180 mm119 mm17.2°11.5°20.6°
250 mm165 mm12.5°8.3°14.9°
350 mm231 mm8.9°5.9°10.7°

Depth of field table#

Total depth of field at each subject distance, using a circle of confusion of 45.5 µm (the 0.030 mm full-frame standard scaled by the crop factor).

FocalAperture50.0 cm1.00 m2.00 m3.00 m5.00 m10.0 mHyperfocal
33 mmf/1.83.5 cm14.6 cm60.4 cm1.41 m4.34 m34.1 m13.3 m
33 mmf/2.85.5 cm22.9 cm97.1 cm2.36 m8.76 m∞8.59 m
33 mmf/47.8 cm33.2 cm1.47 m3.94 m26.6 m∞6.02 m
33 mmf/816.0 cm72.1 cm4.62 m323 m∞∞3.03 m
66 mmf/1.80.8 cm3.5 cm14.6 cm33.2 cm93.5 cm3.87 m53.3 m
66 mmf/2.81.3 cm5.5 cm22.7 cm51.8 cm1.47 m6.34 m34.3 m
66 mmf/41.8 cm7.8 cm32.5 cm74.6 cm2.15 m10.0 m24.0 m
66 mmf/83.6 cm15.7 cm66.3 cm1.56 m4.96 m53.1 m12.0 m
112 mmf/1.80.3 cm1.2 cm4.9 cm11.3 cm31.9 cm1.30 m153 m
112 mmf/2.80.4 cm1.8 cm7.7 cm17.6 cm49.7 cm2.03 m98.7 m
112 mmf/40.6 cm2.6 cm11.0 cm25.2 cm71.2 cm2.93 m69.1 m
112 mmf/81.1 cm5.2 cm22.0 cm50.6 cm1.45 m6.25 m34.6 m
185 mmf/1.80.1 cm0.4 cm1.7 cm4.0 cm11.5 cm47.0 cm418 m
185 mmf/2.80.1 cm0.6 cm2.7 cm6.3 cm17.9 cm73.1 cm269 m
185 mmf/40.2 cm0.9 cm3.9 cm9.0 cm25.6 cm1.05 m188 m
185 mmf/80.3 cm1.7 cm7.7 cm18.0 cm51.3 cm2.11 m94.3 m

Equivalent aperture#

Exposure is identical at the same f-number on any format; equivalence only describes depth of field and total light.

Aperture on this cameraFull-frame equivalent (depth of field)Hyperfocal at 66 mm
f/1.2f/0.879.9 m
f/1.4f/0.968.5 m
f/1.8f/1.253.3 m
f/2f/1.348.0 m
f/2.8f/1.834.3 m
f/4f/2.624.0 m
f/5.6f/3.717.2 m
f/8f/5.312.0 m

Night-sky exposure limits#

Longest exposure before stars trail. The NPF rule accounts for pixel pitch and is stricter than the classic 500 rule — use it for pin-sharp stars on high-resolution sensors. (NPF needs a known resolution and is omitted here.)

Focal length500 rule
21 mm (14 mm eq.)36.1 s
30 mm (20 mm eq.)25.3 s
36 mm (24 mm eq.)21.0 s
53 mm (35 mm eq.)14.3 s
76 mm (50 mm eq.)10.0 s

Open the NPF / 500 rule calculator →

Handheld shutter speed guide#

The reciprocal rule uses the equivalent focal length. High-resolution sensors may need one stop faster than this for pixel-sharp results.

Focal lengthNo stabilisation (1/equiv. focal)With 3-stop ISWith 5-stop IBIS
36 mm1/25 s0.3 s1.3 s
76 mm1/50 s1/6 s0.6 s
152 mm1/100 s1/13 s0.3 s
303 mm1/200 s1/25 s1/6 s

Frequently asked questions#

What is the crop factor of the Hasselblad 500 mech.?

The Hasselblad 500 mech. has a crop factor of 0.66× relative to 35 mm full frame (diagonal 65.6 mm vs 43.3 mm).

What size is the Hasselblad 500 mech. sensor?

54.5 × 36.4 mm (Medium format 53.4 × 40 mm), an area of 1983 mm² — 230% of full frame.

Is the Hasselblad 500 mech. full frame?

No — its sensor is larger than full frame (medium format).

What lens mount does the Hasselblad 500 mech. use?

The Hasselblad 500 mech. uses the Hasselblad V (flange distance 74.90 mm).

How long can I expose the night sky with the Hasselblad 500 mech.?

With a 30 mm lens (20 mm equivalent) the 500 rule gives 25 s.

Sources & licences#

Last updated October 03, 2026 · How we calculate · Sources

Last posts

  1. Why Lenses Cost More Than Camera Bodies
  2. Why Used Camera Gear Holds Value So Well
  3. Best Surge Protectors for Photography Editing Workstations
  4. Can Cheap Flash Triggers Damage Your Camera
  5. Do You Need a UPS for Your NAS and Why It Matters
  6. Best NAS for Photography Teams and How to Choose One
  7. Why Photos Look the Same After Buying Expensive Lenses
  8. Choosing NAS Drive Size for Growing Photo Archives
  9. Is an LTO Tape Drive Overkill for a Small Photography Studio
  10. Can Counterfeit Filters Damage Lens Coatings