Compact

Konica Minolta Dimage Z20

The Konica Minolta Dimage Z20 is a compact with a 1/2.5" sensor measuring 5.7 × 4.3 mm. Its crop factor is 6.05×, so a 50 mm lens frames like 303 mm on full frame. Every number below is calculated for this exact sensor.

1/2.5"6.05× crop
Konica Minolta Dimage Z20 camera
Photo: Plbcr, CC BY-SA 3.0, via Wikimedia Commons
6.05×
Crop factor
5.7×4.3 mm
Sensor size
25 mm²
Area · 3% of full frame

Specifications#

Model
Dimage Z20
Camera type
Compact
Sensor size
5.7 × 4.3 mm (1/2.5" sensor)
Crop factor
6.05×

Specifications merged from Wikidata and Lensfun. Spot an error? Tell us.

Sensor size compared#

1/2.3" sensorKonica Minolta Dimage Z20
The Konica Minolta Dimage Z20 sensor (highlighted) drawn to scale against common formats. Its area is 3% of a full-frame sensor, which collects about 5.1 stops less total light at the same exposure.

Focal length equivalents & field of view#

Multiply any focal length by 6.05 to get the full-frame field of view. For fixed-lens cameras use the real focal length printed on the lens (e.g. “6.1–18.3 mm”), not the 35 mm equivalent.

Lens on this cameraFull-frame equivalentHorizontalVerticalDiagonal
4 mm24 mm71.1°56.4°83.6°
4.5 mm27 mm64.9°51.0°76.9°
5 mm30 mm59.5°46.4°71.1°
6 mm36 mm51.0°39.3°61.6°
8 mm48 mm39.3°30.0°48.2°
10 mm61 mm31.9°24.2°39.3°
12 mm73 mm26.8°20.3°33.2°
15 mm91 mm21.6°16.3°26.8°
20 mm121 mm16.3°12.2°20.3°
25 mm151 mm13.1°9.8°16.3°
30 mm182 mm10.9°8.2°13.6°
40 mm242 mm8.2°6.1°10.2°
50 mm303 mm6.5°4.9°8.2°
70 mm424 mm4.7°3.5°5.8°
100 mm605 mm3.3°2.5°4.1°
150 mm908 mm2.2°1.6°2.7°

Depth of field table#

Total depth of field at each subject distance, using a circle of confusion of 5.0 µm (the 0.030 mm full-frame standard scaled by the crop factor).

FocalAperture50.0 cm1.00 m2.00 m3.00 m5.00 m10.0 mHyperfocal
4 mmf/233.9 cm1.99 m∞∞∞∞1.62 m
4 mmf/2.852.8 cm6.82 m∞∞∞∞1.16 m
4 mmf/498.8 cm∞∞∞∞∞81.1 cm
4 mmf/8∞∞∞∞∞∞40.7 cm
7 mmf/210.1 cm41.9 cm1.93 m5.74 m∞∞4.95 m
7 mmf/2.814.2 cm61.1 cm3.32 m18.1 m∞∞3.54 m
7 mmf/420.8 cm95.9 cm9.23 m∞∞∞2.48 m
7 mmf/847.5 cm4.54 m∞∞∞∞1.24 m
12 mmf/23.4 cm13.7 cm55.8 cm1.29 m3.89 m26.1 m14.5 m
12 mmf/2.84.7 cm19.2 cm79.6 cm1.88 m6.25 m264 m10.4 m
12 mmf/46.8 cm27.7 cm1.18 m2.97 m13.0 m∞7.27 m
12 mmf/813.7 cm58.8 cm3.13 m15.3 m∞∞3.64 m
20 mmf/21.2 cm4.9 cm19.7 cm44.6 cm1.25 m5.27 m40.4 m
20 mmf/2.81.7 cm6.8 cm27.6 cm62.7 cm1.78 m7.87 m28.8 m
20 mmf/42.4 cm9.7 cm39.6 cm90.6 cm2.63 m13.1 m20.2 m
20 mmf/84.8 cm19.6 cm81.7 cm1.94 m6.53 m951 m10.1 m

Equivalent aperture#

Exposure is identical at the same f-number on any format; equivalence only describes depth of field and total light.

Aperture on this cameraFull-frame equivalent (depth of field)Hyperfocal at 7 mm
f/1.2f/7.38.24 m
f/1.4f/8.57.07 m
f/1.8f/10.95.50 m
f/2f/12.14.95 m
f/2.8f/16.93.54 m
f/4f/24.22.48 m
f/5.6f/33.91.77 m
f/8f/48.41.24 m

Night-sky exposure limits#

Longest exposure before stars trail. The NPF rule accounts for pixel pitch and is stricter than the classic 500 rule — use it for pin-sharp stars on high-resolution sensors. (NPF needs a known resolution and is omitted here.)

Focal length500 rule
4 mm (24 mm eq.)20.7 s
5 mm (30 mm eq.)16.5 s
6 mm (36 mm eq.)13.8 s
7 mm (42 mm eq.)11.8 s
8 mm (48 mm eq.)10.3 s

Open the NPF / 500 rule calculator →

Handheld shutter speed guide#

The reciprocal rule uses the equivalent focal length. High-resolution sensors may need one stop faster than this for pixel-sharp results.

Focal lengthNo stabilisation (1/equiv. focal)With 3-stop ISWith 5-stop IBIS
4 mm1/25 s0.3 s1.3 s
8 mm1/50 s1/6 s0.6 s
17 mm1/100 s1/13 s0.3 s
33 mm1/200 s1/25 s1/6 s

Lens#

The Konica Minolta Dimage Z20 has a built-in, non-interchangeable lens. Use the real focal length of that lens with the tables above; its full-frame equivalent is that number × 6.05.

Frequently asked questions#

What is the crop factor of the Konica Minolta Dimage Z20?

The Konica Minolta Dimage Z20 has a crop factor of 6.05× relative to 35 mm full frame (diagonal 7.1 mm vs 43.3 mm).

What size is the Konica Minolta Dimage Z20 sensor?

5.7 × 4.3 mm (1/2.5"), an area of 25 mm² — 3% of full frame.

Is the Konica Minolta Dimage Z20 full frame?

No — its sensor is 1/2.5", which is 35.2× smaller in area than full frame.

How long can I expose the night sky with the Konica Minolta Dimage Z20?

With a 5 mm lens (30 mm equivalent) the 500 rule gives 17 s.

Sources & licences#

Last updated October 03, 2026 · How we calculate · Sources

Last posts

  1. Are Cine Lenses Worth It for Hybrid Shooters
  2. Best Portable SSDs for Mirrorless Video Offloading
  3. Are Lensbaby Lenses Worth Buying for Artistic Portraits
  4. Do Creative Portrait Lighting Gels Damage Your Flash
  5. Choosing the Right SSD Size for a Lightroom Catalogue
  6. Do You Need a Backdrop Stand for Event Photography
  7. Are Printer-Ready Photo Booth Kits Worth the Investment
  8. Best Thunderbolt Docks for Monitors and Card Readers
  9. Are LED Lights Safe for Newborn Photography?
  10. Choosing a Docking Station for Multiple Photo Drives